| Parameter |
SDI Configuration |
Units |
Comments |
CONFIGURATION |
| Type of ESPs Supported (1) |
ESP-64HD ESP-32HD |

|
incorporating DTC option |
|
Number of FIU's Supported per 8400 SP
|
2 |
each |
for 2048 channels, max |
Number of SDI's Supported per FIU
|
1 |
each |
for 1024 channels, max |
Number of ESP's Supported per SDI |
12 or 16 |
each |
for 1024 channels, max depends on SDI model |
PERFORMANCE |
Static Accuracy @100% Range
@ 33% Range (2) |
±0.03 ±0.05
±0.06 ±0.10
±0.05 ±0.08
±0.10 ±0.16 |
% FS % FS
% FS % FS
%
FS % FS
% FS % FS |
after span cal (ranges > 5 psid)
after rezero (ranges > 5 psid
after span cal (ranges < 5 psid)
after rezero (ranges < 5 psid)
after span cal (ranges > 5 psid)
after rezero (ranges > 5 psid)
after span cal (ranges < 5 psid)
after rezero (ranges < 5 psid)
|
Total Thermal Stability @100% Range
@ 33% Range (2) |
±0.001 ±0.002
±0.002 ±0.004
±0.0015 ±0.003
±0.003 ±0.005 |
% FS/șC % FS/șC
% FS/șC %
FS/șC
% FS/șC % FS/șC
% FS/șC % FS/șC |
typical (ranges > 5 psid)
worst case (ranges > 5 psid)
typical (ranges < 5 psid)
worst case (ranges < 5 psid)
typical (ranges > 5 psid)
worst case (ranges > 5 psid)
typical (ranges < 5 psid)
worst case (ranges< 5 psid) |
| Measurement Rate |
50,000 |
ch/sec |
max (per FIU) |
| A/D Resolution |
16 |
bits |
for SDI |
| Electrical |
 |
SDI |
DTC |
Units |
Comments |
|
32HD |
64HD |
Power Requirements (4)
+5 volts
+12 volts
-12 volts |

|
1200 50 50
|
30
60 20 |
30
85 20 |
ma ma ma |
|
| Environmental/Physical |
8426 FIU |
8411 SDI |
ESP DTC Scanners |
Units |
Comments |
| Calibrated Temp Range |

|
|
0 to 80 |
șC |
 |
| Operating Temp Range |
0 to 50 |
0 to 80 |
-25 to 80 |
șC |
 |
| Storage Temp Range |
-25 to 80 |
-25 to 80 |
-25 to 100 |
șC |
 |
| Size |

|
4.25x1.89x2.13
10.81x4.80x5.40 |
3.15x1.35x1.00 8.02x3.46x2.55 |
in cm |
L x W x H (for ESP-64HD) |
| Weight |

|
14 400 |
7.0 195 |
oz g |
max (for ESP-64HD |