Version 2.45 Changes

  1. Improved TCP/IP reliability. The host must however wait 10 seconds after closing a connection before attempting to open a new connection.
  2. Enhanced temperature voltage calibration.

Command Summary:  

  1. New commands:
    1. Set temperature gain reference coefficient: The ‘v01118 dddd..dddd’ command sets the gain reference coefficient used for the temperature signal where dddd..dddd is type float (follow this command with the ‘w07’ command to make the selection non-volatile).  Example: v01118 .99999 sets the reference coefficient to .99999.
    2. Query temperature gain reference coefficient: The ‘u01118’ command queries the temperature gain reference coefficient.


 